Datacenters are growing in this age of information and technology. As they incorporate more elaborate equipment and scale up, their heat management takes precedence. This is because any damage due to overheating to the servers and networking equipment could disrupt the flow of data and cascade into bigger glitches. Working on heat management has a direct influence on the power efficiency of a datacenter. This also means that heat management encapsulates not only overheating and subsequent damage to equipment but also needless to say, the power electronics design should and also does include cooling strategies of the Servers, Storage and Networking (SSN) components of the datacenters.
The design for the cooling system conventionally has two components: the Mechanical Refrigeration Sub-System (MRSS) and the Terminal Cooling Sub-System (TCSS). The MRSS comprises an array of equipment, including chillers, pumps, and cooling towers, tasked with providing the requisite cooling capacity to mitigate the heat dissipated within the Datacenter (DC) environment. Meanwhile, the TCSS serves as the conduit through which heat is transferred from the interior of the facility to the exterior environment, employing various techniques such as air-cooling, liquid-cooling, or free-cooling to achieve optimal heat dissipation. Here, we dive into how air-cooling is employed in datacenters and scale up to the whole heat management infrastructure of the DC system.
To discuss the latest market trends and insights
Air-Cooling Technology in Datacenters
Air-cooling technology is the cornerstone of heat management strategies in DC. Renowned for its simplicity in maintenance and reasonable operational costs, air-cooling operates through a cyclical airflow mechanism within the Terminal Cooling Sub-System (TCSS), utilizing the cold supply from the Computer Room Air Conditioner (CRAC) – following the conventional skeleton of DC cooling systems.
Terminal Cooling of Air-Cooling
When it comes to air-cooling, implementations vary based on the equipment densities within datacenters, leading to distinct branches aimed at enhancing power consumption efficiency at different levels of cooling terminals. One of the most sophisticated implementations is chip-oriented cooling, yet its practicality is limited due to increased implementation and maintenance costs. Therefore, attention is often directed towards room-level, row-level, and rack-level air-cooling technologies, each offering unique advantages and facing distinct challenges.
Room-Level Cooling
Room-level cooling strategies focus on the comprehensive dissipation of heat within the facility, typically employing a raised floor layout for cold air distribution. The computer rooms in air-cooled datacenters are often equipped with plenums under the raised floor and ceiling vents, facilitating the continuous circulation of cold airflow. However, challenges arise from issues such as hot air recirculation (HAR) and cold air bypass (CAB), which can lead to inefficient cooling and potential hot spots within the racks. Various airflow management techniques, including air containment systems (ACS), are employed to mitigate these challenges and optimize cooling efficiency.
Row-Level Cooling
Row-level cooling offers a more localized approach by positioning CRAC units in close proximity to ICT devices, thereby reducing airflow paths and enhancing cooling efficiency. Inter-row cooling and overhead cooling configurations are commonly employed, each presenting unique advantages and challenges. Inter-row cooling facilitates a rear-to-front airflow distribution between adjacent racks, while overhead cooling transforms the hot aisle into an up-flow design. However, challenges such as the cold air bypass effect may persist, particularly in rooms with vertical temperature differences.
Rack-Level Cooling
Rack-level cooling represents the pinnacle of localized cooling solutions, with rack coolers mounted directly within the racks themselves. This configuration minimizes airflow paths, optimizes cooling distribution, and offers flexibility in adjusting cooling capacity based on specific rack requirements. While rack-level cooling boasts unparalleled controllability and efficiency, installation costs and maintenance requirements may pose challenges.
Mechanical Refrigeration of Air-Cooling
In tandem with terminal cooling, the Mechanical Refrigeration Sub-System (MRSS) plays a crucial role in dissipating heat to the outdoor environment through dual refrigeration cycles (DRCs). The heat transfer cycle involves the continuous production and circulation of cooled water, while the heat rejection cycle dissipates absorbed heat into the ambient environment via cooling towers. Optimization methods for cooling equipment are essential to minimize the power consumption of the MRSS and enhance overall cooling efficiency.
Evolution of Datacenters is Includes Cooling Systems Too
While air-cooling technology serves as a foundational element in the cooling infrastructure of datacenters, the pursuit of optimal cooling efficiency extends beyond conventional methodologies. The efficacy of DC cooling systems must be weighed against their energy consumption, which often constitutes a significant portion of the facility’s overall power usage. To address this challenge, adaptive control strategies have emerged as a means of dynamically adjusting cooling parameters in response to real-time conditions. Leveraging methodologies such as model-predictive control (MPC) or reinforcement learning control (RLC), these strategies optimize cooling efficiency while minimizing energy expenditure, thereby ensuring the optimal performance of the facility’s cooling infrastructure.
Our brochure and sample reports highlighting the scope and coverage of our research solutions.
Yet, the evolution of DC cooling extends beyond mere energy efficiency, encompassing the integration of Cyber–Physical–Social Systems (CPSSs) to augment operational intelligence. By amalgamating data streams from human operators, equipment sensors, and environmental variables, CPSSs facilitate nuanced decision-making processes that optimize cooling efficiency in real-time, transcending the limitations of traditional control methodologies.
However, human involvement remains indispensable in the orchestration of DC cooling operations. To facilitate seamless interaction between operators and cooling systems, user-friendly interfaces are deployed to enable remote monitoring and control. These interfaces empower technicians to oversee and fine-tune cooling operations with precision, ensuring optimal performance and reliability.
Furthermore, the advent of AI gives way to a new era in DC cooling, wherein machine learning algorithms analyze historical data to derive insights and autonomously optimize cooling parameters. This iterative process of optimization promises to enhance cooling efficiency and reliability, heralding a future where DC cooling systems evolve dynamically in response to changing environmental conditions and operational requirements.
In summary, the evolution of datacenter cooling represents a convergence of traditional methodologies and cutting-edge innovations. From the foundational principles of air-cooling technology to the integration of advanced control strategies and AI-driven optimization, the quest for efficient and reliable cooling solutions continues unabated.
As datacenters scale up and embrace the complexities of modern computing environments, the importance of robust cooling infrastructure becomes increasingly evident. By leveraging technological advancements and embracing a holistic approach to heat management, datacenters can not only enhance operational efficiency but also ensure the uninterrupted flow of data critical to the functioning of our digital world.
About Wired and Wireless Technologies (WAWT)
WAWT, a strategic technology analyst and consultancy firm, specializes in the wireless power and power supply industry. Its comprehensive report, titled “AC-DC and DC-DC Merchant Power Supply Market Report” and “External Power Adapters and Chargers Market Report”, offers critical market data, insights, and market intelligence. It provides the latest market size estimates and forecasts for the power supply market, catering to companies across the power supply ecosystem. The report covers product segments, regional segments, and power classes, and includes a detailed analysis of power supply vendors’ market share . Furthermore, it ranks power supply companies based on their revenues, across industry sectors.
For our informative & insightful Newsletter “Power Bulletin”
In summary, WAWT’s report is an invaluable resource for businesses seeking to understand the power supply landscape, make informed decisions, and stay competitive in this dynamic industry.
Reach out to our subject matter experts (SMEs) by emailing analyst@wawt.tech and following our LinkedIn page (WAWT) for the latest market trends and updates on power supplies and allied technologies.